12V 1A 12W SAA AC/DC switching power adaptor ▼
      product:12V 1A 12W SAA AC/DC switching power adaptor
        KRECO P/N:KRE-1201002
        DOWNLOAD / EMAIL NOW        
        Request a Quote: sales@kreco.com.cn
    kreco email address
Details:
12V 1A  series External wall-mount medical power adaptor, 12W AC/DC switching power adapter, Class II, Universal input, customized design.
P/N: 
KRE-SAW91
Model Number: KRE-1201002

General: 12V 1,000mA series medical power adaptor adaptor









Power: 12W
Input:100V~240V~50/60Hz 0.35A
Output: 12V-1,000mA

Model Number: KRE-XXXYYYZ
"XXX"=030-480, The output voltage is DC3.0-48.0V,
"YYY"=001-450, The output current is 0.01-4.5A,
"Z" representing the input plug, 0-European plug, 1-British plug, 2-the Australian plug, 3-USA plug, 4-Japan plug, 5-China plug, 6-Korea plug. 




Certifications: UL, cUL, CE, CCC, PSE, GS, TUV, SAA, CQC, ETL, CETL, CB, FCC, EMC, RoHS
BS En60065/AS/NZS60065
IEC60065/EN60065/UL60065
J60065/GB8900/K60065




No load input power (240V AC): 0.1W
Input voltage: 100 to 240V AC
Input Frequency: 50 to 60Hz
Input current: 350mA maximum
Inrush current (240V AC): 25A, cold 25°C
Efficiency: 85% maximum




DC output voltage: 12V DC
DC output current: 1,000mA
Output voltage precision: 5%
Regulation: ±1% line, ±5% load
Ripple/noise: 100mV
DC output cord AWG: With cable
Wire length: 1.5m
DC connector : 2.1X5.5mm , 2.5X5.5mm , optional




AN/NZS CISPR 13:2012
En55020: 2007
EN61000-3-3: 2008
EN61000-3-2: 2006+A2: 2009
En55013: 2001+A1: 2003+A2: 2006
FCC Part15 Class B
Subpart B: 2014




Thermal shutdown capability(Auto recovery)
Over-load protection(OLP)
Over-current protection(OCP)
Over-voltage protection(OVP)
Short-circuit protection(SCP)
Over temperature protection (OTP)




Low loss
High efficiency: consumption
Efficiency Level: V
LED indication
Light and convenient plug-in
With fuse, LED light indicator
High reliability
Low-temperature
Low working temperature and low ripple noise




Storage humidity: 10 to 95% RH
Operating humidity: 10 to 95% RH
Storage temperature: -20 to 80°C
Operating temperature: 0 to 40°C




Leakage current: 0.25mA maximum at 264V AC
MTBF: meet MIL-HDBK-217F over 50,000hrs, full load, 25°C
Burn-in: 100% full load, 40°C, 4hrs minimum
Inrush resistance: 100MΩ min at 500V
Inrush current: 50A (maximum) at 240V (15A at 90V AC, 18A at115V AC, 31A at 230V AC, and 33A at 264V
Withstanding voltage: 3kV 1minute 10mA max, between primary and secondary




PE bag
Individual white box
Quantity: 100 pcs/carton
Gross weight: 9kg maximum
Carton dimensions: 470 x 350 x 240mm